Machine parameters¶
Command: post_models(“r_flux_magnet”,”r”)
Returns the permanent-magnet flux-linkage in the variable with the freely selectable identifier “r”.
Example:
| post_models("r_flux_magnet","r")
| flux_magnet = r[1] -- Magnet flux [Vs]
Command: post_models(“r_ldq/r”,”r”)
Returns the permanent-magnet flux-linkage in the variable with the freely selectable identifier “r”.
Example:
| post_models("r_ldq/r","r")
| Ld = r[1] -- Ld [H]
| Lq = r[2] -- Lq [H]
| Ra = r[3] -- R stator [Ohm]