Psid and Psiq identification

Call: Rotating Machine (r/phi-coordinate-system)

Data for the “Psid/Psiq identification” procedure

Example for the call:

m.arm_length      =        100.000 --   Effect. armature length          [mm]
m.num_pol_pair    =          2.000 --   Number of Pole pairs           (>= 1)
m.npols_gen       =          1.000 --   Number of Poles simulated      (>= 1)
m.speed           =       3000.000 --   Speed: rotate                 [1/min]
m.skew_angle      =          0.000 --   Skew angle                  [Deg; mm]
m.nu_skew_steps   =          0.000 --   No of skew sect: >0:finite;0:infinite
m.num_par_wdgs    =          1.000 --   Number of parallel Windings    (>= 1)
m.fc_radius       =         34.250 --   Radius air-gap center (torque)   [mm]
m.maxid           =          0.000 --   Max value Id-current              [A]
m.minid           =          0.000 --   Min value Id-current              [A]
m.maxiq           =          0.000 --   Max value Iq-current              [A]
m.miniq           =          0.000 --   Min value Iq-current              [A]
m.delta_id        =          0.000 --   Delta Id                          [A]
m.delta_iq        =          0.000 --   Delta Iq                          [A]
m.nu_move_steps   =         49.000 --   Number of move steps
m.range_phi       =        180.000 --   Move range angle
m.phi_start       =          0.000 --   Start angle \n

m.pocfilename    = 'xyz.poc'
run_models("psd_psq_fast")